Battery Installation - APRILIA Atlantic 300 Service Station Manual

Hide thumbs Also See for Atlantic 300:
Table of Contents

Advertisement

ATLANTIC 300 i.e.

Battery installation

CHECKING AND CLEANING TERMINALS AND
LEADS
Make sure the ignition switch is set to
«OFF».
Lift the saddle.
Unscrew and remove the two screws
«1».
Remove the battery protection.
Check that the cable terminals «2» and leads «3» from the battery are in good conditions
(not corroded or covered by deposits); covered by neutral grease or petroleum jelly.
If necessary:
Disconnect first the negative lead (-) and then the positive one (+).
Brush with a metal bristle brush to remove all signs of corrosion.
Connect again first the positive lead (+) and then the negative one (-).
Cover the leads and terminals with neutral grease or petroleum jelly.
CHECK
In case of malfunction check first that the recharge system works properly.
To check the battery
Remove the battery from the vehicle as follows:
Visually check that:
- there are no signs of sulphation (signalled by white colouring of one or more cells);
- the electrolyte level is between the two "MIN" and "MAX" reference notches;
- the container (outer casing) does not leak.
Charge the battery slowly for at least 10 hours.
With a densimeter check the electrolyte density at every cell, after recharging. If the density
is below 1.26 at any cell or if the off-load voltage is lower than 12V, the battery surely needs
to be replaced.