SPORTCITY CUBE 250 - 300
Turn the key to ''ON'' and wait 10 seconds.
During this operation the service icon flashes at a
1 Hz frequency.
Sealed battery
Commissioning sealed batteries
If the motorcycle is provided with a sealed battery, the only maintenance required is to check if it is
charged and to recharge it, if necessary. These operations should be carried out before delivering the
vehicle, and on a six-month basis while the vehicle is stored in open circuit. Besides upon pre-delivery,
it is therefore necessary to check the battery charge and recharge it, if required, before storing the
motorcycle and afterwards every 6 months.
INSTRUCTIONS FOR BATTERY REFRESH AFTER OPEN CIRCUIT STORAGE
1. Voltage check
•
2.
Before installing the battery on the vehicle, check the open circuit voltage with a standard
tester.
•
If voltage is over 12.60V, the battery can be installed without any refresh.
•
If voltage is below 12.60 V, a renewal recharge is required as explained in 2).
3. Constant-voltage battery charge mode
•
4.
Constant-voltage charge equal to 14.40-14.70V
•
Initial charge current equal to 0.3-0.5 of the battery rated capacity
•
Charge time:
•
10 to 12 h recommended Minimum 6 h Maximum 24 h
5. Constant-current battery charge mode
•
6.
Charge current equal to 1/10 of the battery rated capacity
Battery installation
VRLA battery (valve-regulated lead-acid battery) Maintenance Free (MF)
WARNING
BATTERY ELECTROLYTE IS TOXIC AND IT MAY CAUSE SERIOUS BURNS. IT CONTAINS SUL-
PHURIC ACID. AVOID CONTACT WITH YOUR EYES, SKIN AND CLOTHING. IF IT ACCIDENTALLY
COMES INTO CONTACT WITH YOUR EYES OR SKIN, WASH WITH ABUNDANT WATER FOR
APPROX. 15 MIN. AND SEEK MEDICAL ATTENTION IMMEDIATELY.
IF ACCIDENTALLY SWALLOWED, IMMEDIATELY DRINK LARGE QUANTITIES OF WATER OR
MILK FOLLOWED BY MAGNESIUM MILK, BEATEN EGG OR VEGETABLE OIL. SEEK IMMEDIATE
MEDICAL ATTENTION.
Electrical system