CHAPTER 7    SNMP Traps

Analog Line Left Off-hook Alarm

The alarm is applicable only to FXS interfaces.
Alarm
OID
Description
Alarm
Source
Event Type
Probable
Cause
Severity
Major
Clear

Media Alarms

Media Realm Bandwidth Threshold Alarm

Alarm
OID
Default
Severity
Event
Table 7-49: acAnalogLineLeftOffhookAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.141
The alarm is sent when an analog FXS phone is left off-hook for a user-
defined time, configured by the FXSOffhookTimeoutAlarm parameter.
Board#1/SipAnalogEp#<id>
equipmentAlarm
Condition
FXS phone is left off-hook for a user-
defined time (configured by the
FXSOffhookTimeoutAlarm
parameter)
FXS phone returns to on-hook
position or the phone's hook-flash
button is pressed.
Table 7-50: acMediaRealmBWThresholdAlarm
acMediaRealmBWThresholdAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.87
ProcessingErrorAlarm
Mediant 800 SBC | SNMP Reference Guide
acAnalogLineLeftOffhookAlarm
Text
"Left Offhook
Line N"
-
- 152 -
Corrective Action
Place the phone's
handset on the
hook (on-hook
position).
-

Hide quick links: