Kemppi A7 MIG Welder 350 Operating Manual page 20

Table of Contents

Advertisement

Welding parameters for WiseRoot+ process (Edit channel 2/6)
Menu item
Value range
1/6
WFSpeed
WFS min -
WFS max
2/6
WFS max
1.2 - 11.0 m/min
3/6
WFS min
1.2 - 11.0 m/min
4/6
FineTuning
FineTuningMin -
FineTuningMax
5/6
FineTuningMax
-9.0 ... +9.0
6/6
FineTuningMin
-9.0 ... +9.0
*
These are system limits. Actual limits come from the selected welding curve.
Default value
Description
From curve
Set the wire feed speed in
0.05 m/min steps from 0.5
to 5.0 m/min and in 0.1 m/
min steps above 5.0 m/min.
*
From curve
Set the upper limit for the
WFSpeed value.
*
From curve
Set the lower limit for the
WFSpeed value.
0
Adjust the base current (arc
heat) of the curve up and
down (0 = no adjustment).
+9.0
Set the upper limit for the
FineTuning value.
-9.0
Set the lower limit for the
FineTuning value.
© Kemppi Oy 2017
Welding parameters for WiseThin+ process (Edit channel 2/6)
Menu item
Value range
1/7
WFSpeed
WFS min -
WFS max
2/7
WFS max
0.7 - 25.0 m/min
3/7
WFS min
0.7 - 25.0 m/min
4/7
FineTuning
FineTuningMin -
FineTuningMax
5/7
FineTuningMax
-9.0 ... +9.0
6/7
FineTuningMin
-9.0 ... +9.0
7/7
Dynamics
-9 ... +9
*
These are system limits. Actual limits come from the selected welding curve.
20
A7 MIG Welder
Default value
Description
From curve
Set the wire feed speed
in 0.05 m/min steps from
0.5 to 5.0 m/min and in
0.1 m/min steps above 5.0
m/min.
*
From curve
Set the upper limit for the
WFSpeed value.
*
From curve
Set the lower limit for the
WFSpeed value.
0
Adjust the base current
(arc heat) of the curve
up and down (0 = no
adjustment).
+9.0
Set the upper limit for the
FineTuning value.
-9.0
Set the lower limit for the
FineTuning value.
0
Control the arc behavior in
short circuit. A lower value
results in a softer arc and
a higher value results in a
rougher arc.
1735