Welding parameters for Pulse MIG process (Edit channel 2/6)
Menu item
Value range
1/8
WFSpeed
WFS min -
WFS max
2/8
WFS max
0.7 - 25.0 m/min
3/8
WFS min
0.7 - 25.0 m/min
4/8
FineTuning
FineTuningMin
FineTuningMax-
5/8
FineTuningMax
-9.0 ... +9.0
6/8
FineTuningMin
-9.0 ... +9.0
7/8
Dynamics
-9 ... +9
8/8
Pulse current
-10 ... +15 %
*
These are system limits. Actual limits come from the selected welding curve.
Default value
Description
From curve
Set the wire feed speed in
0.05 m/min steps from 0.5 to
5.0 m/min and in 0.1 m/min
steps above 5.0 m/min.
*
From curve
Set the upper limit for the
WFSpeed value.
*
From curve
Set the lower limit for the
WFSpeed value.
0
Adjust the welding voltage
(arc length) of the welding
curve up and down (0 = no
adjustment).
+9.0
Set the upper limit for the
FineTuning value.
-9.0
Set the lower limit for the
FineTuning value.
0
Control the arc behavior in
short circuit. A lower value
results in a softer arc and
a higher value results in a
rougher arc.
0 %
Adjust the pulse current up
and down.
© Kemppi Oy 2017
Welding parameters for Double Pulse MIG process (Edit channel 2/6)
Menu item
Value range
1/10
WFSpeed
WFS min -
WFS max
2/10
WFS max
0.7 - 25.0 m/min
3/10
WFS min
0.7 - 25.0 m/min
4/10
FineTuning
FineTuningMin -
FineTuningMax
5/10
FineTuningMax
-9.0 ... +9.0
6/10
FineTuningMin
-9.0 ... +9.0
7/10
Dynamics
-9 ... +9
8/10
Pulse current
-10 ... +15 %
9/10
DPulseAmp
0.1 - 3.0, CURVE
10/10
DPulseFreq
0.4 - 8.0 Hz, CURVE
*
These are system limits. Actual limits come from the selected welding curve.
19
A7 MIG Welder
Default value
Description
From curve
Set the wire feed speed in
0.05 m/min steps from 0.5
to 5.0 m/min and in 0.1 m/
min steps above 5.0 m/min.
*
From curve
Set the upper limit for the
WFSpeed value.
*
From curve
Set the lower limit for the
WFSpeed value.
0
Adjust the welding voltage
(arc length) of the welding
curve up and down (0 = no
adjustment).
+9.0
Set the upper limit for the
FineTuning value.
-9.0
Set the lower limit for the
FineTuning value.
0
Control the arc behavior in
short circuit. Lower value
results to softer and higher
value to rougher arc.
0 %
Adjust the pulse current up
and down.
CURVE
Adjust the amplitude of
the wire feed speed, or use
the value from the welding
curve.
CURVE
Adjust the frequency of
the double pulse, or use
the value from the welding
curve.
1735