template-set
Syntax
Context
Description
Default
Parameters
inactive-timeout
Syntax
Context
Description
Default
Parameters
Page 644
Unlike other commands and parameters where the default state is not indicated in the configuration
file. The shutdown and no shutdown states are always indicated in system generated configuration
files.
template-set {basic | mpls-ip | l2-ip}
config>cflowd>collector
This command specifies the set of templates sent to the collector when using cflowd Version 9 or
Version 10.
basic
basic — Basic flow data is sent.
mpls-ip — Extended flow data is sent that includes IP and MPLS flow information.
l2-ip — Extended flow data is sent that includes Layer 2 (ethernet) and IP flow information.This
template is only applicable for v10(IPFIX) collectors.
inactive-timeout seconds
no inactive-timeout
config>cflowd
This command specifies the amount of time, in seconds, that must elapse without a packet matching a
flow in order for the flow to be considered inactive.
The no form of this command resets the inactive timeout back to the default of 15 seconds.
Note: Existing flows will not inherit the new inactive-timeout value if this parameter is changed
while cflowd is active. The inactive-timeout value for a flow is set when the flow is first created in
the active cache table and does not change dynamically.
15
seconds — Specifies the amount of time, in seconds, that must elapse without a packet matching a
flow in order for the flow to be considered inactive.