echo-receive
Syntax
echo-receive echo-interval
no echo-receive
Context
config>router>bfd>bfd-template
Description
This command sets the minimum echo receive interval, in milliseconds, for a session. This is not used
by a BFD session for MPLS-TP.
Default
no echo-receive
Parameters
echo-interval — Specifies the echo receive interval.
multiplier
Syntax
multiplier multiplier
no multiplier
Context
config>router>bfd>bfd-template
Description
This command specifies the detect multiplier used for a BFD session. If a BFD control packet is not
received for a period of multiplier x receive-interval, then the session is declared down.
Default
3
Parameters
multiplier — Specifies the multiplier.
type
Syntax
[no] type cpm-np
Context
config>router>bfd>bfd-template
Description
This command selects the CPM network processor as the local termination point for the BFD session.
This is enabled by default.
Default
type cpm-np
triggered-policy
Syntax
triggered-policy
no triggered-policy
7750 SR OS Router Configuration Guide
Values
100 ms — 100,000 ms in 1 ms increments
Default
100
Values
3 — 20, integers
Default
3