Mitsubishi Q00JCPU User Manual page 613

Q series, logic
Hide thumbs Also See for Q00JCPU:
Table of Contents

Advertisement

APPENDICES
ACPU
Special
Special
Special
Relay after
Relay for
Relay
Conversion
Modification
M9103
SM1103
SM323
M9104
SM1104
SM324
M9108
SM1108
SM90
M9109
SM1109
SM91
M9110
SM1110
SM92
M9111
SM1111
SM93
M9112
SM1112
SM94
M9113
SM1113
SM95
M9114
SM1114
SM96
M9180
SM1180
SM825
M9181
SM1181
SM822
M9182
SM1182
SM821
M9196
SM1196
SM325
M9197
SM1197
M9198
SM1198
M9199
SM1199
TableApp.11 Special relay
Name
Meaning
OFF : Continuous transition
Presence/absence
not effective
of continuous
ON : Continuous transition
transition
effective
Continuous
OFF : When transition is
transition
completed
suspension flag
ON : When no transition
Step transition
watchdog timer
start (equivalent of
SD90)
Step transition
watchdog timer
start (equivalent of
SD91)
Step transition
watchdog timer
start (equivalent of
SD92)
Step transition
OFF : Watchdog timer reset
watchdog timer
ON : Watchdog timer reset
start (equivalent of
start
SD93)
Step transition
watchdog timer
start (equivalent of
SD94)
Step transition
watchdog timer
start (equivalent of
SD95)
Step transition
watchdog timer
start (equivalent of
SD96)
Active step
OFF : Trace started
sampling trace
ON : Trace completed
completion flag
OFF : Trace not being
Active step
executed
sampling trace
ON : Trace execution under
execution flag
way
Active step
OFF : Trace disable/suspend
sampling trace
ON : Trace enable
permission
Operation output
OFF : Coil output OFF
at block stop
ON : Coil output ON
I/O numbers
SM
SM
to be
1197
1198
displayed
OFF
OFF
X/Y0 to 7F0
Switch between
blown fuse and I/O
X/Y800 to
ON
OFF
verification error
display
X/Y1000 to
OFF
ON
17F0
X/Y1800 to
ON
ON
1FF0
Data recovery of
OFF : Data recovery disabled
online sampling
ON : Data recovery enabled
trace/status latch
Details
• Set whether continuous transition will be performed for the
block where the "continuous transition bit" of the SFC
information device is not set.
• OFF during operation in the continuous transition mode or
during continuous transition, and ON when continuous
transition is not executed.
• Always ON during operation in the no continuous
transition mode.
• Turns ON when the measurement of the step transition
watchdog timer is started.
Turning this relay OFF resets the step transition watchdog
timer.
• Set when sampling trace of all specified blocks is
completed. Reset when sampling trace is started.
• Set when sampling trace is being executed.Reset when
sampling trace is completed or suspended
• Selects sampling trace execution enable/disable.
ON
: Sampling trace execution is enabled.
OFF : Sampling trace execution is disabled. If turned off
during sampling traceexecution,trace is
suspended.
• Selects the operation output when block stop is executed.
ON
: Retains the ON/OFF status of the coil being used
by using operation output of the step being
executed at block stop.
OFF : All coil outputs are turned off. (Operation output
by the SET instruction is retained regardless of
the ON/OFF status of M9196.)
Switches I/O numbers in the fuse blow module storage
registers (SD1100 to SD1107) and I/O module verify error
FF0
storage registers (SD1116 to SD1123) according to the
combination of ON/OFF of the SM1197 and SM1198.
• Recovers the setting data stored in the CPU module at
restart when sampling trace/status latch is executed.
• SM1199 should be ON to execute again. (Unnecessary
when writing the data again from peripheral devices.)
Appendix 1 Special Relay List
9
Corresponding CPU
10
11
QnA
Qn(H)
QnPH
QnA
QnA
Qn(H)
QnPH
App
- 18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents