Download Print this page
Mitsubishi QS03NB-U-HW Manuallines
Mitsubishi QS03NB-U-HW Manuallines

Mitsubishi QS03NB-U-HW Manuallines

Safety programmable controller

Advertisement

Quick Links

Mitsubishi Safety Programmable Controller
Thank you for purchasing the Mitsubishi safety programmable
controller MELSEC-QS Series.
Prior to use, please read both this manual and detailed manual
thoroughly and familiarize yourself with the product.
© 2008 MITSUBISHI ELECTRIC CORPORATION
Safety Guideline
MODEL
MODEL
CODE
IB(NA)-0800424-B(0809)MEE
QS03NB-U-HW
13JY84

Advertisement

loading

Summary of Contents for Mitsubishi QS03NB-U-HW

  • Page 1 Mitsubishi Safety Programmable Controller Safety Guideline Thank you for purchasing the Mitsubishi safety programmable controller MELSEC-QS Series. Prior to use, please read both this manual and detailed manual thoroughly and familiarize yourself with the product. MODEL QS03NB-U-HW MODEL 13JY84 CODE IB(NA)-0800424-B(0809)MEE ©...
  • Page 2: Safety Precautions

    SAFETY PRECAUTIONS (Always read these instructions before using this equipment.) Before using the product, please read this manual, the relevant manuals introduced in this manual, standard programmable controller manuals, and the safety standard carefully and pay full attention to safety to handle the product correctly.
  • Page 3 [Design Precautions] DANGER When a safety programmable controller detects an error in an external power supply or a failure in programmable controller main module, it turns off all the outputs. Create an external circuit to securely stop the power of hazard by turning off the outputs.Incorrect configuration may result in an accident.
  • Page 4 [Design Precautions] CAUTION Do not bunch the wires of external devices or communication cables together with the main circuit or power lines, or install them close to each other. They should be installed 100 mm (3.94 inch) or more from each other. Not doing so could result in noise that would cause malfunctions.
  • Page 5 [Wiring Precautions] DANGER Be sure to shut off all phases of the external supply power used by the system before wiring. Not completely turning off all power could result in electric shock or damage to the product. When energizing or operating the module after installation or wiring, be sure to close the attached terminal cover.
  • Page 6 [Wiring Precautions] CAUTION Ground the FG and LG terminals correctly. Not doing so could result in electric shock or malfunctions. Use a solderless terminal with insulation sleeve for wiring of a terminal block. Use up to two solderless terminals for a single terminal. Use applicable solderless terminals and tighten them with the specified torque.
  • Page 7 [Startup and Maintenance precautions] DANGER Do not touch the terminals while power is on. Doing so could result in electric shock. Correctly connect the battery. Also, do not charge, disassemble, heat, place in fire, short circuit, or solder the battery. Mishandling of battery can cause overheating, cracks, or ignition which could result in injury and fires.
  • Page 8 [Startup and Maintenance precautions] CAUTION The online operations performed from a PC to a running safety programmable controller (Program change when a safety CPU is RUN, device test, and operating status change such as RUN-STOP switching) have to be executed after the manual has been carefully read and the safety has been ensured.
  • Page 9 [Disposal Precautions] CAUTION When disposing of this product, treat it as industrial waste. When disposing of batteries, separate them from other wastes according to the local regulations. (For details of the battery directive in EU member states, refer to QSCPU User's Manual (Hardware Design, Maintenance and Inspection).
  • Page 10: Revisions

    SAFETY PRECAUTIONS This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 11: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ................A-1 Revisions ...................... A-9 CONTENTS ....................A-10 About Manual ..................... A-11 1. OVERVIEW ....................1 1.1 Included Parts ..................1 2. GENERAL SPECIFICATIONS ............... 2 2.1 General Specifications ................2 A-10...
  • Page 12: About Manual

    About Manual Introduction Manual Before constructing or designing the safety-related system, be sure to read the following manual. Manual No. Manual name (Model code) Safety Application Guide Explains the overview and construction method of the SH-080613ENG safety-related system, laying and wiring examples, application (13JR90) programs, etc.
  • Page 13: Overview

    1. OVERVIEW This manual describes the precautions for using the QS series module in safety. 1.1 Included Parts The following tables list the parts included with the corresponding modules. (1) Safety CPU module Product Name Quantity Module Battery (Q6BAT) (2) Safety main base unit for QS series Product Name Quantity Unit...
  • Page 14: General Specifications

    2. GENERAL SPECIFICATIONS 2.1 General Specifications The performance specifications of QS series programmable controller are shown in Table3.1. Table 3.1 General Specifications Item Specifications Operating ambient 0 to 55 temperature Storage ambient -40 to 75 temperature Operating ambient 5 to 95%RH, non-condensing humidity Storage ambient 5 to 95%RH, non-condensing...
  • Page 15 Please confirm the following product warranty details before using this product. 1. Limited Warranty and Product Support. a. Mitsubishi Electric Company ("MELCO") warrants that for a period of forty two(42) months after date of delivery from the point of manufacture or three(3) years from date of Customer's purchase, whichever is less, Mitsubishi MELSEC Safety programmable controllers (the "Products") will be free from defects in material and workmanship.
  • Page 16 2. Limits of Warranties. a. MELCO does not warrant or guarantee the design, specify, manufacture, construction or installation of the materials, construction criteria, functionality, use, properties or other characteristics of the equipment, systems, or production lines into which the Products may be incorporated, including any safety, fail-safe and shut down systems using the Products.
  • Page 17 3. Limits on Damages. a. MELCO'S MAXIMUM CUMULATIVE LIABILITY BASED ON ANY CLAIMS FOR BREACH OF WARRANTY OR CONTRACT, NEGLIGENCE, STRICT TORT LIABILITY OR OTHER THEORIES OF RECOVERY REGARDING THE SALE, REPAIR, REPLACEMENT, DELIVERY, PERFORMANCE, CONDITION, SUITABILITY, COMPLIANCE, OR OTHER ASPECTS OF THE PRODUCTS OR THEIR SALE, INSTALLATION OR USE SHALL BE LIMITED TO THE PRICE PAID FOR PRODUCTS NOT AS WARRANTED.
  • Page 18 4. Delivery/Force Majeure. a. Any delivery date for the Products acknowledged by MELCO is an estimated and not a promised date. MELCO will make all reasonable efforts to meet the delivery schedule set forth in Customer's order or the purchase contract but shall not be liable for failure to do b.
  • Page 19 MEMO...
  • Page 20 Hsiang, Taipei Hsine, Taiwan Gothaer Strasse 8 D-40880 Ratingen, Tel : +886-2-2299-2499 GERMANY Tel : +49-2102-486-0 Korea Mitsubishi Electric Automation Korea Co., Ltd. 1480-6, Gayang-dong, Gangseo-ku Mitsubishi Electric Europe B.V. UK Seoul 157-200, Korea Branch Tel : +82-2-3660-9552 Travellers Lane, Hatfield, Hertfordshire., AL10 8XB, U.K.