PUTE instruction

G(P)_PUTE
Serial Modem
Structured ladder/FBD
G_PUTE
EN
ENO
Un*
d
s1
s2
The following instruction can go in the dotted squares.
G_PUTE, GP_PUTE
■Executing condition
Instruction
G_PUTE
GP_PUTE
■Argument
Input/output
Name
argument
Input argument
EN
Un*
s1
s2
Output argument
ENO
d
Setting
Internal device
*1
data
Bit
Word
(s1)
(s2)
(d1)
*1 Local devices and file registers per program cannot be used as setting data.
Processing details
This instruction registers a user frame.
Setting data
Device
Item
(s1)[0]
Registration/
deletion
specification
(s1)[1]
Registration/
deletion result
ST
ENO:=
(EN, Un*, s1, s2, d);
G_PUTE
Executing condition
Description
Executing condition
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/
O number in three digits)
Variable that stores control data
Start number of the device that stores read
registration data
Execution result
Variable that turns ON upon completion of the
instruction
d[1] also turns ON at the time of error completion.
R, ZR
J\
Bit
Setting data
Specify whether to register/delete the user frame of the number
specified by (s1)[2].
1: Registered
3: Deleted
The instruction completion status is stored.
0: Normal completion
Other than 0: Error completion (error code)
Data type
Bit
ANY16
Array of ANY16 [0..3]
ANY16
Bit
Array of bit [0..1]
U\G
Zn
Word
Setting range
1, 3
5 MODULE DEDICATED INSTRUCTION
5.3 Serial Communication Instruction
Constant
Others
Setting side
User
System