■Slave station setting data
Device
Item
(s2)[0]
Setting for 1 to
64 modules
(s2)[63]
*1 Set the same number which was set for Number of connected modules in the control data.
*2 Setting a value outside the setting range in the setting of slave station type results in error completion of the instruction.
■Reserved station specification data
Device
Item
(s3)[0]
Specification for
1 to 64
(s3)[3]
stations
*1 Set the parameter up to the largest station number set in the slave station setting data.
*2 Set the parameter only to the start station number of the module for the remote station/local station/intelligent device station that
occupies two or more stations.
5 MODULE DEDICATED INSTRUCTION
120
5.4 Network Dedicated Instruction
Setting data
Set the slave station type, the number of occupied slave stations, and the station
*1
number as shown below.
b15
to
b12 b11
to
Default parameter setting is '0101H to 0140H (station number: 1 to 64, number of
occupied slave stations: 1, type of slave station: Ver.1 compatible remote I/O station)'
Setting of station number
1 to 64 (BIN setting)
Setting of the number of occupied slave stations
The setting value for the number of occupied slave stations is described below.
1H: 1 station
2H: 2 stations
3H: 3 stations
4H: 4 stations
Setting of slave station type
The setting value for the slave station type is described below.
0H: Ver.1 compatible remote I/O station
1H: Ver.1 compatible remote device station
2H: Ver.1 compatible intelligent device station
5H: Ver.2 compatible single remote device station
6H: Ver.2 compatible single intelligent device station
8H: Ver.2 compatible double remote device station
9H: Ver.2 compatible double intelligent device station
BH: Ver.2 compatible quadruple remote device station
CH: Ver.2 compatible quadruple intelligent device station
EH: Ver.2 compatible octuple remote device station
FH: Ver.2 compatible octuple intelligent device station
Setting data
Specify the reserved station.
0: Not specified
*1
1: Specified
b14
b15
s3 [0]
16
15
s3 [1]
32
31
s3 [2]
48
47
s3 [3]
64
63
1 to 64 in the table indicates a station number.
Default parameter setting is '0: Not specified' for all stations.
b8 b7
to
b0
Station number
Number of occupied
slave stations
Type of slave station
*2
*2
b13
b12
b3
b2
b1
to
14
13
to
4
3
2
30
29
to
20
19
18
46
45
to
36
35
34
62
61
to
52
51
50
Setting
range
1 to 40H
1 to 4H
0 to FH
Setting
range
b0
1
17
33
49
Setting side
User
Setting side
User