Setting
Internal device
*1*2
data
Bit
Word
(d1)
(d2)
*1 Local devices and file registers per program cannot be used as a device which is used in setting data.
*2 In addition to the setting data, the ZNWR instruction is executed using the following fixed values.
Channel used by host station: Channel 2
Arrival monitoring time (monitoring time until instruction completion): 10 seconds
Number of resends for arrival monitoring timeout: 5 times
Processing details
This instruction writes data to devices of a programmable controller CPU on another station. (In units of words)
• Specify devices of the target station's CPU within the range allowed for the host station CPU when writing
data to the devices with the ZNWR instruction.
(Target station's start device number (d1) where data are written) + (Write points - 1)  (End device No. of host
station's CPU
• Specify the host station's start device number (d1) within the range allowed for storing write data. (Example)
When D150 and after the area in the host station's CPU has been already used
Good example (D50 is specified in (
Host station CPU
D0
100 words
D99
*3 End device No. of the device in the host station CPU, and whose device name is same as in (d1)
R, ZR
J\
Bit
*3
)
).)
Other station CPU
D50
D149
D150
U\G
Zn
Word
Bad example (D100 is specified in (
Host station CPU
Other station CPU
D0
100 words
D99
: Data to be written with ZNWR instruction
: Area already used by target station's CPU
: Duplicated area