Device
Item
(s2)[103]
CPU status
monitoring
(s2)[104]
setting
(s2)[105]
* Error
(s2)[106]
monitoring
(s2)[107]
11th
(s2)[108]
* 11th block
(s2)[109]
(s2)[110]
(s2)[111]
5 MODULE DEDICATED INSTRUCTION
78
5.3 Serial Communication Instruction
Condition
Fixed value
agreement
transmission
User frame
output start
pointer
Number of user
frame
transmissions
Modem
connection data
No.
Setting data
Specify a fixed value to monitor the CPU status.
Specify the start pointer of the to which the user
frame number for condition agreement transmission
for this block is set.
0: No specification (at constant cycle transmission
and notification)
1 to 100: Start pointer
Specify the number of user frame transmissions
(outputs) for condition agreement transmission for
this block.
0: No specification (at constant cycle transmission
and notification)
1 to 100: Number of transmissions
Specify the data number for modem function
connection when making notification in condition
agreement transmission for this block.
0: No specification (at data transmission and
constant cycle transmission)
BB8H to BD5H: Connection data number (flash
ROM)
8001H to 801FH: Connection data number (buffer
memory)
Setting
Setting side
range
1
User
0
0
1
5
1
0, 1 to 100
User
0, 1 to 100
User
0,
User
BB8H to
BD5H,
8001H to
801FH