G(P)_PRR
Serial Modem
Structured ladder/FBD
G_PRR
EN
ENO
Un*
s
The following instruction can go in the dotted squares.
G_PRR, GP_PRR
■Executing condition
Instruction
G_PRR
GP_PRR
■Argument
Input/output
argument
Input argument
Output argument
Setting
Internal device
*1
data
Bit
(s)
(d)
*1 Local devices and file registers per program cannot be used as setting data.
Processing details
This instruction sends data by user frame according to the specification in user frame specification area for transmission
during communication using the nonprocedural protocol.
5 MODULE DEDICATED INSTRUCTION
68
5.3 Serial Communication Instruction
ST
ENO:=
G_PRR
d
Executing condition
Name
Description
EN
Executing condition
Un*
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/
O number in three digits)
s
Variable that stores control data
ENO
Execution result
d
Variable that turns ON upon completion of the
instruction
d[1] also turns ON at the time of error completion.
R, ZR
Word
(EN, Un*, s, d);
J\
U\G
Bit
Word
Data type
Bit
ANY16
Array of ANY16 [0..4]
Bit
Array of bit [0..1]
Zn
Constant
Others