Message (User-Specified Data) Communication - Mitsubishi Electric MELSEC-L Special Instructions Manual

Melsec-q/l structured programming manual
Hide thumbs Also See for MELSEC-L:
Table of Contents

Advertisement

Message (user-specified data) communication

J(P)_SEND, G(P)_SEND
CC IE C
CC IE F
NET/H
Structured ladder/FBD
J_SEND
EN
ENO
Jn*
d
s1
s2
The following instruction can go in the dotted squares.
J_SEND, JP_SEND, G_SEND, GP_SEND
■Executing condition
Instruction
J_SEND
G_SEND
JP_SEND
GP_SEND
■Argument
Input/output
argument
Input argument
Output argument
Setting
Internal device
*1
data
Bit
(s1)
(s2)
(d)
*1 Local devices and file registers per program cannot be used as setting data.
Processing details
This instruction sends data to another station.
5 MODULE DEDICATED INSTRUCTION
144
5.4 Network Dedicated Instruction
Ether
G_SEND
EN
ENO
Un*
d
s1
s2
Executing condition
Name
Description
EN
Executing condition
Jn*
Network number of the host station (1 to 239, 254)
254: Network specified in "Valid module during
other station access"
Un*
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/
O number in three digits)
s1
Variable that stores control data
s2
Start number of the host station's device that stores
write data
ENO
Execution result
d
Variable that turns ON upon completion of the
instruction
d[1] also turns ON at the time of error completion.
R, ZR
Word
ST
ENO:=
(EN, Jn*, s1, s2, d);
J_SEND
ENO:=
(EN, Un*, s1, s2, d);
G_SEND
J\
U\G
Bit
Word
Data type
Bit
ANY16
ANY16
Array of ANY16 [0..17]
ANY16
Bit
Array of bit [0..1]
Zn
Constant
Others

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q

Table of Contents