Setting data
Device
Item
(s1)[0]
Error completion
type
(s1)[1]
Completion
status
(s1)[2]
Channel used
by host station
(s1)[3]
Target station's
CPU type
(s1)[4]
Target station
network No.
(s1)[5]
Target station
No.
(s1)[6]
(s1)[7]
Number of
resends
5 MODULE DEDICATED INSTRUCTION
158
5.4 Network Dedicated Instruction
Setting data
...
b15
b7
0
(1)
Error completion type (bit 7)
Specify the clock data setup status at the time of error completion.
0: Clock data at the time of error completion is not set in the area starting from
(s1)[11].
1: Clock data at the time of error completion is set in the area starting from (s1)[11].
The instruction completion status is stored.
0: Normal completion
Other than 0: Error completion (error code)
Specify the channel used by the host station.
1 to 8: Channel
Specify the type of the target station CPU.
Setting values are as follows.
■Ethernet
• 0000H: Target station CPU/host system CPU (Specified data are the same as
'03FFH'.)
*1
• 03FFH
: Target station CPU/host system CPU
■MELSECNET/H CC-Link IE
• 0000H: Target station CPU/host system CPU (Specified data are the same as
'03FFH'.)
*2
• 03E0H
: Multi-CPU No. 1/target station CPU (single CPU system)
*2
• 03E1H
: Multi-CPU No. 2
*2
• 03E2H
: Multi-CPU No. 3
*2
• 03E3H
: Multi-CPU No. 4
*1
• 03FFH
: Target station CPU/host system CPU
Specify the network number of the target station.
1 to 239: Network number
254: Specify this when 254 has been set in Jn. (Network specified in 'Valid module
during other station access')
Specify the station number of the target station.
Setting values are as follows.
■Station number specification
• MELSECNET/H: 1 to 64
• When the host station is Universal model QCPU in Ethernet or CC-Link IE
Controller Network: 1 to120
• When the host station is anything other than Universal model QCPU in Ethernet or
CC-Link IE Controller Network: 1 to 64
• Master station in CC-Link IE Field Network: 125 (7DH)
• Local station or the intelligent device station in CC-Link IE Field Network: 1 to 120
■Group specification (target station is anything other than CC-Link IE Field Network)
81H to A0H: All stations in group numbers 1 to 32 (Available only at clock data writing
and remote RUN/STOP)
Group No.1
81
H
Group No.2
82
H
to
Group No.32
A0
H
■All stations specification
FFH: All stations of the target network number (Except the host station.) (Available
only at clock data writing and remote RUN/STOP)
To specify a group or all stations.
• Specify '0000H' or '03FFH' for the target station's CPU type ((s1)[3]).
• Group specification cannot be set for the station of the CC-Link IE Field Network.
• It cannot be confirmed if the data are written to the target station normally. Confirm
the device of the target station of the write destination.
(Fixed value)
• For instruction execution
Specify the number of resends when the instruction is not completed within the
monitoring time specified in (s1)[8].
• At instruction completion
The number of resends (result) is stored
...
...
b4
b0
0
1
0
1
Setting
Setting side
range
0011H, 0091H
User
System
1 to 8
User
■Ethernet
User
0000H,03FFH
■MELSECNE
T/H, CC-Link
IE
0000H, 03E0H
to 03E3H,
03FFH
1 to 239, 254
User
1 to 120, 125
User
(7DH), 81H to
A0H, FFH
0
User
0 to 15
User
0 to 15
System