Frequently Asked Questions
LAN
If multiple RFP 22/24 base stations are installed, the blinking LED indicates that
synchronisation is not finished.
The LED of the RFP 22/24 is continuously lit up, but one of the cordless DECT
devices is indicating "No connection".
You have not registered this DECT device. Configure a port in the Configurator
and start the enrolment procedure (PBX Configuration: Devices: DECT Phones
menu).
Is it possible to increase the time for the enrolment procedure?
You must manually enter the IPEI of the DECT device in the Configurator. The
enrolment time is then increased to one hour (PBX Configuration: Devices: DECT
Phones menu).
Another manufacturer's DECT device is not functioning.
Check whether the DECT device supports the DECT GAP standard. In the Configu-
rator, also make sure GAP is set for this DECT device (PBX Configuration:
Devices: DECT Phones menu).
The startup procedure of the RFP 22/24 take a long time? What is the reason?
This behaviour may indicate a problem with the reference clock. Refer also to What
are some of the causes for problems when sending and/or receiving faxes? starting on
page 193.
19.4
LAN
Why is it not possible to establish a network connection with the
OpenCom 510?
Check whether the LEDs for the switch and the PC's network card are indicating a
connection.
Check the LEDs for the LAN functions of the OpenCom 510.
To check whether there is a network connection with your OpenCom 510, enter
the "ping IP address" command in "Run" in the Windows Start menu (e.g. ping
192.168.99.254).