Item
Extend I/F Setting
CH No.
Driver
Detail Setting
POINT
POINT
POINT
Channel No., drivers, [RS232 Setting]
(1) Channel No.2 to No.4
Use the channel No.2 to No.4 when using the Multi-channel function.
For details of the Multi-channel function, refer to the following.
(2) Drivers
The displayed items for a driver differ according to the settings [Manufacturer], [Controller Type] and [I/F].
When the driver to be set is not displayed, confirm if [Manufacturer], [Controller Type] and [I/F] are correct.
(3) [RS232 Setting] of GT14
Do not use [RS232 Setting] of GT14 for other than the 5V power feeding to the RS-232/485 signal conversion
adaptor.
For details, refer to the following manual.
1.1.3

Precautions

(1) Precautions for changing model
(a) When devices that cannot be converted are included.
When setting of [Manufacturer] or [Controller Type] is changed, GT Designer3 displays the device that
cannot be converted (no corresponding device type, or excessive setting ranges) as [??]. In this case, set
the device again.
(b) When the changed Manufacturer or Controller Type does not correspond to the network.
The network will be set to the host station.
(c) When the Manufacturer or Controller Type is changed to [None]
The GT Designer3 displays the device of the changed channel No. as [??]. In this case, set the device
again.
Since the channel No. is retained, the objects can be reused in other channel No. in a batch by using the
[Device Bach Edit], [CH No. Batch Edit] or [Device List].
1 - 12
1. PREPARATORY PROCEDURES FOR MONITORING
1.1 Setting the Communication Interface
Set the communication unit attached to the extension interface of the GOT.
Set the CH No. according to the intended purpose.
The number of channels differs depending on the GOT to be used.
0: Not used
1 to 4: Used for connecting a controller of channel No. 1 to 4 set in Setting connected equipment (Channel
setting)
5 to 7: Used for barcode reader connection, RFID connection, and PC remote operation connection
* : For the gateway function, MES interface function, Ethernet download, report function,
hard copy (For printer output), video/RGB input, RGB output, multimedia function,
CF card unit, CF card extension unit, sound output, and external I/O or operation panel
Set the driver for the device to be connected.
None
Each driver for connected devices
Make settings for the transmission speed and data length of the communication driver.
Refer to each chapter of the equipment to be connected to the GOT.
Mitsubishi Electric Products 20. MULTI-CHANNEL FUNCTION
[Setting the communication] section in each chapter
GT14 User's Manual 7.11 RS-232/485 Signal Conversion Adaptor