When using the printer unit, sound output unit, or external I/O unit
The printer unit, sound output unit, or external I/O unit can be installed in any position (1st to 3rd stage) of the
extension interface.
Example: When installing a printer unit
When using the video input unit, RGB input unit, video/RGB input unit, RGB output unit, or
multimedia unit
Install the video input unit, RGB input unit, video/RGB input unit, RGB output unit, or multimedia unit at the 1st stage
of the extension interface.If any of these units is installed in the 2nd stage or above, the unit cannot be used.
When any of these units is used, the communication units indicated below must be installed in the 2nd stage of the
extension interface.
Communication unit
Bus connection unit
MELSECNET/H communication
unit
CC-Link IE controller
network communication unit
CC-Link communication unit
Example: When installing a video input unit and a MELSECNET/H communication unit
1 - 22
1. PREPARATORY PROCEDURES FOR MONITORING
1.3 Option Devices for the Respective Connection
Communication
unit
Printer unit
GT15-QBUS2,
GT15-ABUS2
GT15-J71LP23-25,
GT15-J71BR13
GT15-J71GP23-SX
GT15-J61BT13
MELSECNET/H
communication unit
Video/RGB
input unit
Printer unit
Communication
unit
Model
Video/RGB
input unit
MELSECNET/H
communication unit