Item
Select the steps to store two
32bit Storage
words (32-bit data).
(Default: LH Order)
Select the communication
*2
protocol
Protocol
(Default: UDP/IP)
Select the communication
Format
format.
(Default: 1)
Specify the number of bytes of
Interrupt Data Length
interrupt data.
(Default: 1)
Set whether or not to output
Special Interrupt
the special interrupt code.
Output
(Default: none)
Set whether or not to perform
*3
a living confirmation.
Living Confirmation
(Default: No)
Set the sampling to perform a
Living Confirmation
living confirmation.
*4
Cycle
(Default: 20s)
*1
Click the [Setting] button and perform the setting in the [GOT
IP Address Setting] screen.
*2
For the interrupt output, select [TCP/IP].
*3
Select [Yes] only when [Protocol] is [TCP/IP].
*4
The setting value can be changed when the [Living
Confirmation] is [Yes].
GT15, GT12
Item
Set the IP address of the GOT.
GOT IP Address
(Default: 192.168.0.18)
3 - 70
3. MICROCOMPUTER CONNECTION (ETHERNET)
3.5 GOT Side Settings
Description
Range
LH Order/
HL Order
TCP/IP
UDP/IP
1 to 9
1 / 2 / 4
Yes or No
Yes/No
10 to 100s
Description
Range
0.0.0.0 to
255.255.255.
255
Item
Set the subnet mask for the
sub network. (Only for
connection via router)
Subnet Mask
If the sub network is not used,
the default value is set.
(Default: 255.255.255.0)
Set the router address of the
default gateway where the
Default Gateway
GOT is connected. (Only for
connection via router)
(Default: 0.0.0.0)
Set the GOT port No. for
Ethernet Download
Ethernet download.
Port No.
(Default: 5014)
Set the GOT port No. for the
GOT Communication
connection with the Ethernet
Port No.
module.
(Default: 5021)
Specify the time period from
the GOT startup until GOT
Startup Time
starts the communication with
the PLC CPU.
(Default: 3sec)
Set the delay time for reducing
the load of the network/
Delay Time
destination PLC.
(Default: 0ms)
Select the steps to store two
32bit Storage
words (32-bit data).
(Default: LH Order)
Select the communication
*1
protocol
Protocol
(Default: UDP/IP)
Select the communication
Format
format.
(Default: 1)
Specify the number of bytes of
Interrupt Data Byte
interrupt data.
(Default: 1)
Set whether or not to output
Special Interrupt Code
the special interrupt code.
(Default: none)
Set whether or not to perform
*2
a living confirmation.
Living Confirmation
(Default: No)
Set the sampling to perform a
Living Confirmation
living confirmation.
*3
Cycle
(Default: 20s)
*1
For the interrupt output, select [TCP/IP].
*2
Select [Yes] only when [Protocol] is [TCP/IP].
*3
The setting value can be changed when the [Living
Confirmation] is [Yes].
Description
Range
0.0.0.0 to
255.255.255.
255
0.0.0.0 to
255.255.255.
255
1024 to 5010.
5014 to
65534
(Except for
5011, 5012,
5013 and
49153)
1024 to 5010.
5014 to
65534
(Except for
5011, 5012,
5013 and
49153)
3 to 255sec
0 to 10000
( 10ms)
LH Order/
HL Order
TCP/IP
UDP/IP
1 to 9
1 / 2 / 4
Yes or No
Yes/No
10 to 100s

Advertisement