Cisco Catalyst 3750 Metro Command Reference Manual page 511

Hide thumbs Also See for Catalyst 3750 Metro:
Table of Contents

Advertisement

Chapter 2 Catalyst 3750 Metro Switch Cisco IOS Commands
Examples
This is an example of output from the show interfaces interface-id transceiver properties command:
Switch# show interfaces gigabitethernet1/0/1 transceiver properties
Name : Gi1/0/1
Administrative Speed: auto
Operational Speed: auto
Administrative Duplex: auto
Administrative Power Inline: enable
Operational Duplex: auto
Administrative Auto-MDIX: off
Operational Auto-MDIX: off
This is an example of output from the show interfaces interface-id transceiver detail command:
Switch# show interfaces gigabitethernet1/0/3 transceiver detail
ITU Channel not available (Wavelength not available),
Transceiver is externally calibrated.
mA:milliamperes, dBm:decibels (milliwatts), N/A:not applicable.
++:high alarm, +:high warning, -:low warning, -- :low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are uncalibrated.
Port
------- ------------------
Gi1/0/3 41.5
Port
-------
Gi1/0/3
Port
-------
Gi1/0/3
<output truncated>
This is an example of output from the show interfaces transceiver supported-list command:
Switch# show interfaces transceiver supported-list
Transceiver Type
------------------
DWDM GBIC
DWDM SFP
RX only WDM GBIC
DWDM XENPAK
DWDM X2
DWDM XFP
CWDM GBIC
CWDM X2
CWDM XFP
XENPAK ZR
X2 ZR
XFP ZR
Rx_only_WDM_XENPAK
XENPAK_ER
X2_ER
OL-9645-10
High Alarm
Temperature
Threshold
(Celsius)
(Celsius)
----------
110.0
High Alarm
Voltage
Threshold
(Volts)
(Volts)
---------------
----------
3.20
4.00
High Alarm
Current
Threshold
(milliamperes)
(mA)
-----------------
----------
31.0
84.0
Cisco p/n min version
-------------------------
ALL
ALL
ALL
ALL
ALL
ALL
NONE
ALL
ALL
ALL
ALL
ALL
ALL
10-1888-03
ALL
High Warn
Low Warn
Threshold
Threshold
(Celsius)
(Celsius)
---------
---------
103.0
-8.0
High Warn
Low Warn
Threshold
Threshold
(Volts)
(Volts)
---------
---------
3.70
3.00
High Warn
Low Warn
Threshold
Threshold
(mA)
(mA)
---------
---------
70.0
4.0
supporting DOM
Catalyst 3750 Metro Switch Command Reference
show interfaces transceiver
Low Alarm
Threshold
(Celsius)
---------
-12.0
Low Alarm
Threshold
(Volts)
---------
2.95
Low Alarm
Threshold
(mA)
---------
2.0
2-483