Using The Temperature Input In The Kty Mode; Using The Temperature Input In The Ptc Mode; Figure 29: Connection Of A Kty Sensor; Figure 30: Wiring Examples In The Ptc Mode - KEB COMBIVERT F5 Instructions For Use Manual

Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

ELEcTrIcAL INSTALLATION
ATTENTION

6.7.3 Using the temperature input in the KTY mode

connection of a KTY sensor
Figure 29:
Connection of a KTY sensor

6.7.4 Using the temperature input in the PTc mode

If the temperature input is operated in the PTC mode, the user is provided with all pos-
sibilities within the specified resistance range. This can be:
Wiring examples in the PTc mode
Thermal contact (NC contact)
Temperature sensor (PTC)
Mixed sensor chain
Figure 30:
Wiring examples in the PTC mode
If no evaluation of the input is required, the function can be switched off with Pn.12 =
"7" (CP.28) (standard in operating mode "GENERAL").Alternatively, a bridge can be
installed between T1B and T2B.
KTY or PTc cables and sensors
► Do not lay KTY or PTC cable from the motor (also screened) together
with control cables!
► KTY or PTC cable within the motor cable only permitted with double
shielding!
► KTY sensors may not be used in connection with other detections.
Otherwise incorrect measurements will be the result.
T1B
+
-
KTY84
T2B
T1B
T2B
T1B
T2B
T1B
T2B
63