Specification And Connection Of The Temperature Detection; Table 40: Specification Of The Temperature Input For K- And A-Control - KEB COMBIVERT S6 Series Instructions For Use Manual

Hide thumbs Also See for COMBIVERT S6 Series:
Table of Contents

Advertisement

brAKe cONTrOL AND TeMPerATUre DeTecTION fOr K- AND A- cONTrOL

4.3.2 Specification and connection of the temperature detection

DANGer
NOTICE
A switchable KTY84/PTC evaluation is implemented in the KEB COMBIVERT. The de-
sired operating mode can be adjusted by software (dr33).
Operating mode (dr33)
0 KTY84/130
1
2 By encoder
3 KTY83/110
4 PT1000
─ Monitoring
Table 40:
66
Use only sensors with basic insulation to mains potential !
Danger to life due to electric shock !
► The inputs of the temperature detection have „basic insulation"
against SELV voltage of the control.
► A system voltage (Phase – PE) of 300 V is defined.
Malfunctions due to incorrect cable or laying!
Malfunctions of the control due to capacitive or inductive coupling.
► Do not lay cables of the motor temperature sensor (also shielded)
together with the control cable !
► Cables of the motor temperature sensor inside the motor cable only
permissible with double shielding !
resistance
0.49 kΩ
1 kΩ
1.72 kΩ
< 0.75 kΩ
PTC in accordance
0.75...1.5 kΩ
with
EN 60947-8
1.65...4 kΩ
(standard)
> 4 kΩ
digital by the encoder channel
0.82 kΩ
1.67 kΩ
2.53 kΩ
1 kΩ
1.38 kΩ
1.75 kΩ
< 0,04 kΩ
> 79,5 kΩ
Specification of the temperature input for K- and A-control
Temperature / state
0°C
100°C
200°C
TA1-TA2 closed
Reset resistance
Tripping resistance
TA1-TA2 open
0°C
100°C
175°C
0°C
100°C
200°C
Short circuit
No connection
(sensor break)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents