13.2.5 (Optional) Disabling Loop Detection on an Interface

Context
Do as follows on the S7700.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface interface-type interface-number
The interface view is displayed.
Step 3 Run:
loop-detection disable
Loop detection is disabled on the interface.
By default, loop detection is enabled on an interface.
----End

13.2.6 (Optional) Setting the Loop Detection Interval on an Interface

Context
Do as follows on the S7700.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
loop-detection interval-time interval-time
The loop detection interval is set on the interface.
By default, the loop detection interval is 5 seconds.
----End

13.2.7 (Optional) Setting the Recovery Time of a Blocked Interface

Context
Do as follows on the S7700.