Cisco Catalyst 2960 Software Configuration Manual page 579

Hide thumbs Also See for Catalyst 2960:
Table of Contents

Advertisement

Chapter 21
Configuring IGMP Snooping and MVR
Configuring IGMP Snooping
This example shows how to set the IGMP snooping querier source address to 10.0.0.64:
Switch# configure terminal
Switch(config)# ip igmp snooping querier 10.0.0.64
Switch(config)# end
This example shows how to set the IGMP snooping querier maximum response time to 25 seconds:
Switch# configure terminal
Switch(config)# ip igmp snooping querier query-interval 25
Switch(config)# end
This example shows how to set the IGMP snooping querier timeout to 60 seconds:
Switch# configure terminal
Switch(config)# ip igmp snooping querier timeout expiry 60
Switch(config)# end
This example shows how to set the IGMP snooping querier feature to version 2:
Switch# configure terminal
Switch(config)# no ip igmp snooping querier version 2
Switch(config)# end