Configuring a System Name and Prompt

Beginning in privileged EXEC mode, follow these steps if summer time in your area does not follow a
recurring pattern (configure the exact date and time of the next summer time events):
Command
Step 1
configure terminal
Step 2
clock summer-time zone date [month
date year hh:mm month date year hh:mm
[offset]]
or
clock summer-time zone date [date
month year hh:mm date month year
hh:mm [offset]]
Step 3
end
Step 4
show running-config
Step 5
copy running-config startup-config
The first part of the clock summer-time global configuration command specifies when summer time
begins, and the second part specifies when it ends. All times are relative to the local time zone. The start
time is relative to standard time. The end time is relative to summer time. If the starting month is after
the ending month, the system assumes that you are in the southern hemisphere.
To disable summer time, use the no clock summer-time global configuration command.
This example shows how to set summer time to start on October 12, 2000, at 02:00, and end on April 26,
2001, at 02:00:
Switch(config)# clock summer-time pdt date 12 October 2000 2:00 26 April 2001 2:00
Configuring a System Name and Prompt
You configure the system name on the switch to identify it. By default, the system name and prompt are
Switch.
If you have not configured a system prompt, the first 20 characters of the system name are used as the
system prompt. A greater-than symbol [>] is appended. The prompt is updated whenever the system
name changes.
If you are accessing a stack member through the stack master, you must use the session
stack-member-number privileged EXEC command. The stack member number range is from 1 through
4. When you use this command, the stack member number is appended to the system prompt. For
example,
for the switch stack is
Catalyst 2960 and 2960-S Switches Software Configuration Guide, Release 15.0(1)SE
5-8
Purpose
Enter global configuration mode.
Configure summer time to start on the first date and end on the second
date.
Summer time is disabled by default.
For zone, specify the name of the time zone (for example, PDT) to be
displayed when summer time is in effect.
(Optional) For week, specify the week of the month (1 to 5 or last).
(Optional) For day, specify the day of the week (Sunday, Monday...).
(Optional) For month, specify the month (January, February...).
(Optional) For hh:mm, specify the time (24-hour format) in hours and
minutes.
(Optional) For offset, specify the number of minutes to add during
summer time. The default is 60.
Return to privileged EXEC mode.
Verify your entries.
(Optional) Save your entries in the configuration file.