No.
25
Set the IMG1L initialization wait timer. (Unit: millisecond)
26
Set the IMG1L mask setting wait timer. (Unit: millisecond)
39
Set switching of the default of LDAP detailed search condition.
40
Set the eLA card touch sound.
41
Set the PS mode 1 (8bit).
42
Set the PS mode 2 (8bit).
57
Set the paper size group.
58
Set the engine sleep (PPOWER HI) wait timer. (Unit: millisecond)
300 msec when the value is 0
59
Set the timer to delay the press/waiting state of the software switch key until
the PPowerOn-enabled judgment flag is turned ON. (Unit: millisecond)
500 msec when the value is 0
60
Set the Secondary Battery charging completion wait timer. (Unit: minute)
120 minutes when the value is 0.
61
Set the pulse trickle charge set timer. (Unit: minute)
300 minutes when the value is 0
65
Set the inquiry wait time at the time of A/D checking (tick).
66
Set the RUI access delay timer. (Unit: second)
60 seconds when the value is 0
67
Set the sleep 2 shift timer. (Unit: second)
12 seconds when the value is 0
76
Set the wait time after a cancellation (E853) processing by the secured print
condition.
Wait for 500 msec when the setting value is 0 (default), and wait for [setting
value] msec when the setting value is other than 0.
77
Set the initial value of the redial interval. (Unit: minute)
Setting value when the clear key is pressed
78
Set the initial value of the pause time. (Unit: minute)
Setting value when the clear key is pressed
79
Set the ring start time of FAX/TEL switch (detailed setting). (Unit: second)
Setting value when the clear key is pressed
80
Set the ring start time of FAX/TEL switch (detailed setting). (Unit: second)
Setting value when the clear key is pressed
81
Set the shift time until automatic shutdown. (Unit: second)
82
120 minutes when the value of the Secondary Battery charging completion
wait timer (Unit: minute) for compliance with Lot26 is 0
83
180 minutes when the value of the pulse trickle charge set timer (unit: minute)
for compliance with Lot26 is 0
*1. An EU directive obligating to design environment-friendly products (eco-design) to facilitate energy saving
Function
*1
*1
277
Setting range
0 to 9999 (Default: 100)
0 to 9999 (Default: 10)
0: Contain
1: Not contain
2: Equal
3: Not equal
4: Begin with (Default)
5: End with
0: OFF, 1: ON (Default)
0 to 60 (Default: 0)
0 to 60 (Default: 0)
Setting values and groups are as follow:
1: AB configuration (PAPER_SIZE_GROUP_
AB)
2: A configuration (PAPER_SIZE_GROUP_A)
3: INCH configuration (PAPER_SIZE_
GROUP_INCH)
4: AB/INCH configuration (PAPER_SIZE_
GROUP_AB_INCH)
The timing of initialization is as follows.
• CLEAR > ALL
• CLEAR >TYPE
• CLEAR > SERVICE DATA
• CLEAR > TEL&USER DATA (because of
synchronizing the values of ATT_ID and
SYSTEM NUMERIC)
• Select country at startup
0 to 9999 (Default: 0)
0 to 9999 (Default: 0)
0 to 9999 (Default: 0)
0 to 9999 (Default: 0)
0 to 9999 (Default: 3)
0 to 9999 (Default: 0)
0 to 9999 (Default: 0)
0 to 9999 (Default: 0)
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999 (Default: 0)
0 to 9999 (Default: 0)