Error Code; Error Code Details - Canon imageRUNNER 2525 Series Service Manual

Hide thumbs Also See for imageRUNNER 2525 Series:
Table of Contents

Advertisement

Error Code

Error Code Details

Ecode
Detail Code
E000
0001
E001
0000
E001
0001
E001
0002
E002
0000
E003
0000
Item
Title
Fixing temperature abnormal rise
Description
The temperature detected by the main thermistor does not rise to
the specified value during startup control.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
Title
Fixing unit temperature rise detection
Description
The reading of the main thermistor is 250 deg C or more continu-
ously for 200 msec.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
Title
Fixing unit temperature rise detection
Description
The hardware circuit detects overheating of the main or sub ther-
mistor for 200 msec.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Replace the DC Controller PCB (PCB4).
Title
Fixing unit temperature rise detection
Description
The reading of the sub thermistor is 295 deg C or more continu-
ously for 200 msec.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
Title
Fixing unit temperature insufficient rise
Description
1.The reading of the main thermistor is less than 115 deg C con-
tinuously for 400 msec 1.3 sec after it has indicated 100 deg C.
2.The reading of the main thermistor is less than 150 deg C con-
tinuously for 400 msec 1.3 sec after it has indicated 140 deg C.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
Title
Low fixing temperature detection after standby
Description
The reading of the main thermistor is less than 140 deg C contin-
uously for 400 msec or more.
201
7. Error/Jam/Alarm
Description