Wiring Ac Power - HySecurity SlideSmart DC 15 Installation And Reference Manual

Slidesmart dc series pad-mounted electromechanical slide gate operator with smart dc controller
Hide thumbs Also See for SlideSmart DC 15:
Table of Contents

Advertisement

W
AC P
IRING
DANGER
!
Turn off AC power at the source (circuit breaker panel) before accessing the wires in the SlideSmart
junction box. Follow facility Lock Out/Tag Out procedures. Make sure both the DC and AC power
switches, on the side of the SlideSmart control box are in the off position. See Figure 2-2.
CAUTION
!
Wiring of gate operators must conform to the NEC standards and comply with all local codes.
If you plan to connect to 208/230VAC power, read the WARNING in Figure 2-2. The voltage
selector switch on the AC Power board must be moved to the 230V position or damage to the
operator will occur and void the Limited Warranty.
Place the power switches in the
OFF position.
WARNING
DO NOT connect the 115VAC service
outlet to 208/230VAC power supply
wires. To use the 115VAC service
outlet on a 208/230VAC installation,
the electrician needs to run an extra
neutral wire to the operator from the
power source and wire the service
outlet per code.
Service outlet
115 VAC wires for the service outlet.
Junction box cover and label
NOTE: For 208VAC a separate transformer option
kit may need to be ordered.
Revision D
OWER
O
DC
POW
OF
O
AC
POW
OF
Figure 2-2.
Power

Wiring AC Power

High voltage
protection cover.
Voltage selector switch is
factory set to 115V.
If power input is 208/230V, move
the switch so 230V appears
and change the label on the
junction box.
2-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slidesmart dc 10fSlidesmart dcs 10f (solar)Slidesmart dcSlidesmart dcs10fSlidesmart dcs15

Table of Contents