Overview of the Smart DC Controller
O
VERVIEW OF THE
The Smart DC Controller uses LED's to indicate active inputs when AC power is present. For operators that
use only DC power, you can push a button to show the active inputs. This button is at the bottom left corner
near the EMERG OPEN input.
On a new operator no active inputs should appear until external accessories and wiring are attached. If any
inputs are active before connecting external wiring, refer to Smart DC Controller Troubleshooting.
COM
COM
COM
COM
COM MON
COM
TERMINALS
COM
COM
COM
STOP
OPEN
CLOSE
OPEN
P ARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ +
+ 24 V
+ 24 V
+24VDC
EMERG
OPEN
Push button to show
active inputs when
using DC power
4-2
S
MART
+24VDC
SHOW
LEDs
USER RELAY 1
Electro-mechanical
Figure 4-2. Smart DC Controller Board
SlideSmart DC Installation and Reference Manual
DC C
ONTROLLER
Amp Draw on Power Supplies
Three power supplies are available:
24VDC, 24VAC, 12VDC
A maximum draw of 1A is allowable when combining
both spade terminals.
NOTE: The 24VDC power supply has four terminals
that can be used in any combination to draw the
available 1A maximum.
For example:
Amp Draw & Accessories connected to 24VDC
0.50A = Four photo eyes (for entrapment protection)
0.25A = Keypad with light
0.015A = Three HY-5A detectors
0.76A
USB PORT
RS-485
USER RELAY 2
COMMUNICATION
Solid state
HY-5A
FREE EXIT
HY-5A
INSIDE LOOP
HY-5A
OUTSIDE LOOP
HY-5A
CENTER LOOP
LOOP