Connecting Accessory Devices
Table 4-3. User-Programmable User Relays - Function Options (Continued)
No.
Name
13
Loitering Alert
14
Gate nearing full travel output
15
Gate Failure output
16
Motor Running output
17
AC Power Failure output
18
DC Power Failure output
19
Flasher Relay
20
Free Exit Loop Vehicle Detector
output
21
Inside Obstruction Vehicle
Detector output
22
Center Loop Detector output
23
External Latching Gate Lock
Output
24
Gate at Partial Open Position
25
DC Power Alert
4-12
Indicates a vehicle is loitering on the Outside Obstruction Loop. Adjustable from 0 delay to
135 seconds delay in 30-second time intervals.
Note: LT - LOITERING ALERT adjustments can be made in the Installer Menu.
Activated when the gate is three feet from full travel in both the open and close directions.
This output is used to reduce the sensitivity of a proximity sensor near the ends of gate travel.
Activated to report occurrence of a problem. Indicates the system is in an Error Mode, Fault
Mode or Entrapment Mode. If active, the gate is disabled.
Active when the motor is running and the gate is in motion.
This relay is normally energized and drops with loss of AC power.
Activated when the battery power is very low, but the output ceases when the battery is dead.
The relay is triggered when the battery is less than 20 Volts.
Controls flashing lights that pulse once per second. The relay is constantly activating except
when the open limit switch is triggered.
Active whenever the Exit Loop is tripped.
Activated when the Inside Obstruction Vehicle Detector is tripped.
Activated when the center loop detector is tripped. Since this input is not used for a sliding
gate, User Relay 22 can be used in combination with a detector to perform the function of an
arming loop detector because there is no associated gate control logic.
Not used in the Smart DC Controller
Active when the partial open position is reached or exceeded.
Deactivates when the software detects a low battery voltage (below 21VDC, but greater than
18VDC) for a duration of 2 seconds or more. To slow battery drain, accessory power loads are
shed. Connect wiring to Relay 2, and then program the Installer Menu item Relay 2 Logic by
entering the number 25 in its data field.
SlideSmart DC Installation and Reference Manual