Turning Both Power Switches On - HySecurity SlideSmart DC 15 Installation And Reference Manual

Slidesmart dc series pad-mounted electromechanical slide gate operator with smart dc controller
Hide thumbs Also See for SlideSmart DC 15:
Table of Contents

Advertisement

Initial Setup

Turning Both Power Switches On

AC and DC power switches are located on the outside edge of the control
box. See Figure 3-1.
After
Programming the Initial Setup
CLOSE
Limits,
Installing the Target
(Power), take the following steps:
1. Turn both power switches ON. The gate moves and searches for the
target magnet to re-establish the limits. An audible beep occurs and a
red light pulsates next to the OPEN button on the Smart DC
Controller which indicates the system is functioning. If AC power is
lost, the rate of flashing slows down. Other indicator lights are
described below.
Note:If the target magnet is not detected by the operator,
"ALERT 15 - NO TARGET" or "LEARN OPEN" appears on the
display. For more information, refer to
2. When the target magnet is detected, the software version briefly
appears on the display, and then one of the following modes appears:
Gate status - indicates the operator is in Run Mode.
Refer to
Run
Alert, fault, and error messages - indicates a problem exists with
the operator which needs to be resolved before the operator can
function properly. Refer to
NOTE
The Smart DC Controller can be powered when either switch is turned on. If the DC power
switch is OFF the motor and batteries are disconnected. The operator will not function (even
though the AC power switch remains on). When the operator is connected to AC power and
both switches are turned ON, the charge level of the battery is being monitored and main-
tained. On a solar-powered operator, the lower power switch connects and disconnects the DC
power from the solar panels.
The flashing red indicator light next to the OPEN
button on the Smart DC Controller is considered the
'heart' beat of the system. It indicates that the
electronics board is receiving power. When AC power
is lost, the rate of flashing slows down. Another
indicator light, above the display, is multi-colored
and corresponds to the action that the operator is
performing:
Green - the operator is stopped.
Flashing yellow - the operator is running.
Red - the operator has experienced an error.
Not lit - AC power is lost. Pressing the SHOW
LEDs button indicates which inputs, if any, are active. Refer to Figure 4-2 for the SHOW LEDs location
on the board.
3-2
Menu,
Establishing the OPEN &
Magnet, and connecting to main power
Mode.
Smart DC Controller
SlideSmart DC Installation and Reference Manual
Installing the Target
Magnet.
Troubleshooting.
Red LED flashes indicating processor
is working.
DC Power
Switch
AC Power
Switch
Figure 3-1.
Multi-colored
LED indicates
power and gate
status.
Figure 3-2.
Revision D

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slidesmart dc 10fSlidesmart dcs 10f (solar)Slidesmart dcSlidesmart dcs10fSlidesmart dcs15

Table of Contents