Adjusting The Ies Sensitivity - HySecurity SlideSmart DC 15 Installation And Reference Manual

Slidesmart dc series pad-mounted electromechanical slide gate operator with smart dc controller
Hide thumbs Also See for SlideSmart DC 15:
Table of Contents

Advertisement

Installer Menu

Adjusting the IES Sensitivity

SlideSmart uses a primary Type-A inherent entrapment sensor (IES) per UL325 Safety Standards. A solid
immovable object blocking the gate will trip the IES and cause the operator to stop and reverse (for two
seconds) and enter safe mode.
The adaptive IES software monitors the average
running motor current while the gate is in motion and
reverses the gate when the current exceeds an
automatically self-adapting average.
The IES display, accessed through the Installer Menu,
allows you to input a number between 0 and 9. The
settings (0 through 6) allow an increasingly higher
threshold (amount of headroom) above the average
current draw before tripping. For IES settings 7
through 9, the current limit is a fixed relatively high
value before the IES will be tripped. The factory setting
is 2, which is adequate for most sites.
CAUTION
Avoid setting the IES sensitivity to a fixed level (7 - 9 setting). The high motor current required
for the IES to trip could cause severe injury or death to people caught in the moving gate.
For IES settings (0 through
6), the motor current is
continually being measured
and the IES threshold
automatically set to trip at the
average current plus the
additional "headroom"
provided by the IES setting
selected.
To prevent false IES trips, the
software boosts the IES
current threshold for one gate
cycle after an IES event, then
returns to the normal
sensitivity threshold.
Over time, degrading gate
hardware and other site
issues, such as road settling or
debris on the gate rail
(V-track) can occur. As the gate hardware ages and becomes stiffer, the SlideSmart motor current increases and
this may create the need to use a higher IES setting level. The higher settings should only be used on a
TEMPORARY basis until the gate, gate track, or wheels are repaired so the gate rolls smoothly with minimum
resistance.
3-18
0
1 2
NOTE: When wind load increases, IES so ware adapts and changes the threshold allowance. The IES threshold
automa cally increases by 50% when the temperature drops below 32°F.
SlideSmart DC Installation and Reference Manual
SE 2
IES SENSITIVITY
OPEN
CLOSE
PREV
NEXT
Typical Opera on
Installer Menu: IES Se ng = 2
3 4 5 6
7 8 9 10 11 12
Time (Seconds)
STOP
MENU
RESET
SELECT
Ini al IES threshold
(First gate cycle only)
Motor current threshold
(at IES Se ng 2)
Motor current
(under typical opera ng
condi ons)
Revision D