Installing a Lock for 12VDC or 24VDC Systems

To install a lock for 12VDC or 24VDC
systems, take the following steps:
1. Connect a wire between COM on
USER 1 RELAY and a COM terminal
on the Smart DC Controller board. See
Figure 6-2.
2. Connect the power lead from the lock
to the appropriate power spade
(+24VDC or +12VDC)
3. Connect the common wire from the
lock to NC on USER 1 RELAY.
Note:Connect to NO on USER 1
RELAY if installing a Solenoid lock.
4. Set the User Relay function in the
Installer Menu to RL1 - 6. Refer to
Setting the User Relay Function in the
Installer
Menu.
Revision D
Installing a MagLock or Solenoid Lock
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
OPEN
P ARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
Connect COM on board
EYE
COM
to COM on USER 1 RELAY.
+ 24 V
EMERG
OPEN
SHOW
LEDs
Figure 6-2.
Reference
2
A ach the power wire from the lock
to the appropriate power spade.
3
1
Connect the COM wire from
the lock.
A Solenoid lock a aches to NO.