HySecurity SlideSmart DC 15 Installation And Reference Manual page 90

Slidesmart dc series pad-mounted electromechanical slide gate operator with smart dc controller
Hide thumbs Also See for SlideSmart DC 15:
Table of Contents

Advertisement

Overview of the Smart DC Controller
PIN 2
PIN 1
Free Exit
Loop Detector
LOOP
Figure 4-4. Standard 11-Pin Box Type Vehicle Detector
V
D
EHICLE
ETECTOR
S
ELECTION
The Standard Quick Close modes are selectable in the Installer Menu. Refer to
The four selectable modes are described as follows:
Mode 1 (Default)
An input from either the Free Exit, Outside Obstruction Loop, Inside Obstruction Loop or the Center
Loop will hold the gate open, reset the close timer, and block all close inputs.
Mode 2
Same function as Mode 1, except the close timer can count to zero even with the Free Exit, Outside
Obstruction Loop, Inside Obstruction Loop or the Center Loop detector inputs active. If the close timer
has counted to zero, the gate will close when all detector inputs are clear.
Mode 3
Same function as Mode 1. However, the close timer is forced to zero when both the OOLD & IOLD are
tripped simultaneously. Additionally, all other close inputs are memorized and the gate closes immediately
when all open commands and vehicle detector inputs are clear.
Mode 4
Full anti-tailgate logic includes Mode 3 functions. In addition, the gate will stop during the opening cycle
when both OOLD & IOLD are tripped simultaneously. When the OOLD & IOLD loops are cleared, the
gate closes immediately. The OOLD & IOLD can be individually set so that, if tripped while closing, the
gate may pause only or reverse to reopen. The free exit detector input is blocked while the gate is closing.
4-8
Inside
Outside
Obstruc on
Obstruc on
Loop Detector
Loop Detector
LOOP
IN OBS LOOP terminal
FREE EXIT LOOP terminal
C
ONFIGURATION AND
SlideSmart DC Installation and Reference Manual
Center
Loop Detector
LOOP
LOOP
Common
OUT OBS LOOP terminal
Q
C
UICK
24VAC or 24VDC
Connect detector to match
its voltage rating
The center loop serves no
gate function but the detector
can be used as an arming loop
when used in conjunction
with User
Relay 22.
CENTER LOOP terminal
M
LOSE
ODE
Table 3-2 on page
3-22.
Revision D

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slidesmart dc 10fSlidesmart dcs 10f (solar)Slidesmart dcSlidesmart dcs10fSlidesmart dcs15

Table of Contents