Installer Menu

Resetting the OPEN and CLOSE Limits

On occasion, the open and close limits may need to be fine-tuned. Resetting the open and close limits is easily
accomplished by accessing the Installer Menu. Examples where resetting the limits is
Replacing the chain or adjusting the chain to the point where it affects the open and close positions
Removing or replacing the target magnet
Setting the LEARN LIMITS display to 1 (erases the open and close target positions from memory)
To re-learn limits, take the following steps:
1. At a gate status display, press the MENU button
twice. The CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET
buttons to enter the Installer Menu.
Release the buttons and the LEARN LIMITS
display appears. It is the first item in the Installer
Menu.
3. Press SELECT, and then NEXT to change the
setting to 1. Press SELECT again.
LEARN OPEN flashes on the display indicating
that operator is ready to relearn the open limit.
4. Hold the OPEN button until the gate reaches
the desired open limit. Release the OPEN
button. (Note that if you go too far, you can
press CLOSE to reverse direction.)
5. Press STOP twice to preserve the open stop
location.
LEARN CLOSE appears on the display.
6. Hold the CLOSE button until the gate slides to
full close. Release the CLOSE button (Note that
if you go too far, you can press OPEN to reverse
direction.)
7. Press STOP twice. The full close stop is retained
in memory. For more information, refer to
Establishing the OPEN & CLOSE
Note:Do not set limits at the physical OPEN and
CLOSE stops. Leave a 1 to 2-inch (2.5 -
5cm) gap to allow for minimal drift.
8. An ALERT 15 message appears on the display.
To clear the alert, perform a full cycle so the
software recognizes the target. Press OPEN, and
then CLOSE. The gate will stop automatically
on the close cycle when it reaches the programmed limit. As the target magnet passes the sensor, the
operator beeps and the ALERT 15 message is cleared.
3-16
Limits.
SlideSmart DC Installation and Reference Manual
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
SELECT
PREV
NEXT
LL 1 (ON)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
necessary,
include:
1. Start at a gate status
display.
2. Access the User
Menu by pressing the
MENU button twice.
3. Access the Installer
Menu, by simul-
taneously, pressing the
OPEN and RESET
buttons.
4. Press SELECT and
change the setting to
1 using the NEXT
button. Press
SELECT again. The
LEARN OPEN
display appears. refer
to steps 4 through 8.