Drive Belt Tension And Alignment - HySecurity SlideSmart DC 15 Installation And Reference Manual

Slidesmart dc series pad-mounted electromechanical slide gate operator with smart dc controller
Hide thumbs Also See for SlideSmart DC 15:
Table of Contents

Advertisement

General Maintenance
D
B
T
RIVE
ELT
ENSION AND
Slide the motor
bracket.
To adjust the tension or replace
the belt, loosen 4 nuts and slide the motor
bracket.
Retighten the fasteners when the adjustments
are complete.
Proper drive belt tension is important for prolonging the life of the drive belt and maintaining the superior
performance of the operator. To check the drive belt tension, take the following steps:
1. Remove the SlideSmart cover and protection plate.
2. Turn off the AC and DC power switch.
3. Check to make sure the pulley is aligned horizontally.
4. With your finger, apply light outward pressure to the drive belt. If it is properly tensioned, it should only
move about 1/16 to 1/8-inch (1.6 to 3.2cm). See Figure 6-17.
5. To replace or re-tension the drive belt. Loosen the four motor bracket nuts and move the motor
accordingly.
6. Retighten the motor bracket nuts.
7. Replace the protection plate and SlideSmart cover.
8. Turn the AC and DC power switches ON. This cycles power which allows the operator to search for the
target magnet and "relearn" its limits.
9. If you don't cycle the power, the operator will not "relearn" its limits to operate properly.
NOTE
Be aware that the gate will cycle open and close (close or open) as it relearns its limits.
See
Resetting the OPEN and CLOSE
6-30
A
LIGNMENT
Figure 6-17.
Limits.
SlideSmart DC Installation and Reference Manual
1/16" to 1/8"
Revision D

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slidesmart dc 10fSlidesmart dcs 10f (solar)Slidesmart dcSlidesmart dcs10fSlidesmart dcs15

Table of Contents