Process - Toshiba e-STUDIO6520C Service Handbook

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO6520C:
Table of Contents

Advertisement

2.6.3

Process

Classific
Code
ation
400
Fuser
Fuser unit error status
counter
556
Image
Image quality closed-loop
control
control/Contrast voltage
573
Image
Abnormality detection
control
count (Y)
Display/0 clearing
574
Image
Abnormality detection
control
count (M)
Display/0 clearing
575
Image
Abnormality detection
control
count (C)
Display/0 clearing
576
Image
Abnormality detection
control
count (K)
Display/0 clearing
© 2008-2011 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08)
Functi
<Accept
Items
on
ALL
ALL
ALL
ALL
ALL
ALL
2 - 131
Default
RAM
Contents
able
value>
0
M
0: No error
<0-71>
1: C411
2: C412
3: C443
4: -
5: C445, C465
6: C446, C466
7: C447, C467
8: C468
9: C449
10: C475 11: C471
12: C472 13: C473
14: C480 15: C481
16: C474 17: C490
18: C468 19: C449
20: C468 21: C449
22: C449 23: C449
24: C447, C446
25: C449 26: C468
27: C449 28: C468
29: C449
30: -
32: C448 33: C467
34: C467
35 to 49: -
50: C452 51: C452
52 to 60: -
61: C461 62: C462
63 to 69: -
70: C464 71: C464
1
M
Sets whether or not
<0-1>
correcting the contrast
voltage in closed-loop
control.
0: Invalid
1: Valid
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]
e-STUDIO5520C/6520C/6530C
Proc
edure
1
31: -
1
1
1
1
1
SELF-DIAGNOSTIC MODE
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio5520cE-studio6530c

Table of Contents