4Precautions - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

Item
Set the communication unit attached to the extension interface of the GOT.
GT21 is not supported.
CH No.
Extension I/F setting
Driver
Detail Setting
1.1.4
Precautions
■1. When using the multiple CPU system
When using the GOT to monitor the multiple CPU system of other stations, select [MELSEC-Q(Multi)/Q-Motion] or
[MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700] for the type, regardless of the host PLC CPU type (QCPU,
QnACPU, ACPU).
When other models are selected, the setting of the CPU No. becomes unavailable.
■2. Precautions for changing model
(1) When devices that cannot be converted are included.
When setting of [Manufacturer] or [Controller Type] is changed, GT Designer3 displays the device that cannot be
converted (no corresponding device type, or excessive setting ranges) as [??]. In this case, set the device again.
(2) When the changed Manufacturer or Controller Type does not correspond to the network.
The network will be set to the host station.
(3) When the Manufacturer or Controller Type is changed to [None]
The GT Designer3 displays the device of the changed channel No. as [??]. In this case, set the device again.
Since the channel No. is retained, the objects can be reused in other channel No. in a batch by using the [Device
Bach Edit], [CH No. Batch Edit] or [Device List].
Set the CH No. according to the intended purpose.
The number of channels differs depending on the GOT to be used.
0: Not used
1 to 4: Used for connecting a controller of channel No. 1 to 4 set in Setting connected equipment (Channel
setting)
5 to 8: Used for barcode function, RFID function, remote personal computer operation function (serial)
A: Used for the video/RGB display function, multimedia function, external I/O function, operation panel
function, RGB output function, report function, hard copy function (with a printer), sound output function.
Set the driver for the device to be connected.
• Each communication driver suitable to the channel numbers
• Each communication driver for connected devices
Set the detailed settings for the communication driver.
Refer to each chapter of the equipment to be connected to the GOT.
POINT
POINT
POINT
Channel No., drivers, [RS232 Setting]
(1) Channel No.2 to No.4
Use the channel No.2 to No.4 when using the Multi-channel function.
For details of the Multi-channel function, refer to the following.
Mitsubishi Products 19. MULTI-CHANNEL FUNCTION
(2) Drivers
The displayed items for a driver differ according to the settings [Manufacturer], [Controller
Type] and [I/F].
When the driver to be set is not displayed, confirm if [Manufacturer], [Controller Type] and [I/
F] are correct.
[Setting the communication interface] section in each chapter
Description
1.1 Setting the Communication Interface
1
1 - 13

Advertisement

Table of Contents
loading

Table of Contents