Mitsubishi Electric GOT2000 Series Connection Manual page 280

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

(a)
When sharing communication settings between multiple channel numbers
The table below shows the settings for the GS device.
GS device
GS570
GS571
GS572
GS573
GS574
GS575
GS576
(b)
When configuring individual communication settings for specific channel numbers
The table below shows the settings for the GS device.
GS device
Ch1
Ch2
GS590
GS597
GS591
GS598
GS592
GS599
GS593
GS600
GS594
GS601
GS595
GS602
GS596
GS603
6 - 12
6.5 Device Range that Can Be Set
Description
Command selection
Function Code "01"
Specification for the max. number of coil
read times
Function Code "02"
Specification for the max. number of input
relay read times
Function Code "03"
Specification for the max. number of holding
register read times
Function Code "04"
Specification for the max. number of input
register read times
Function Code "0F"
Specification for the max. number of
multiple-coil write times
Function Code "10"
Specification for the max. number of
multiple-holding register write times
Ch3
Ch4
GS604
GS611
Command selection
Function Code "01"
GS605
GS612
Specification for the max. number of
coil read times
Function Code "02"
GS606
GS613
Specification for the max. number of
input relay read times
Function Code "03"
GS607
GS614
Specification for the max. number of
holding register read times
Function Code "04"
GS608
GS615
Specification for the max. number of
input register read times
Function Code "0F"
GS609
GS616
Specification for the max. number of
multiple-coil write times
Function Code "10"
GS610
GS617
Specification for the max. number of
multiple-holding register write times
Bit0:0Using Function Code "0F"
1Not using Function Code "0F"
Bit1:0Using Function Code "10"
1Not using Function Code "10"
0:1000
1 to 2000: Specify the maximum number.
Other than above: 2000
0:1000
1 to 2000: Specify the maximum number.
Other than above: 2000
0:125
1 to 125: Specify the maximum number.
Other than above: 125
0:125
1 to 125: Specify the maximum number.
Other than above: 125
0:800
1 to 800: Specify the maximum number.
Other than above: 800
When Bit0 of GS570 is "1", the function code "0F" is not used, and therefore
the setting of GS575 will be disabled.
0:100
1 to 100: Specify the maximum number.
Other than above: 100
When Bit1 of GS570 is "1", the function code "10F" is not used, and
therefore the setting of GS576 will be disabled.
Description
Bit0:0Using Function Code "0F"
1Not using Function Code "0F"
Bit1:0Using Function Code "10"
1Not using Function Code "10"
0:1000
1 to 2000: Specify the maximum number.
Other than above: 2000
0:1000
1 to 2000: Specify the maximum number.
Other than above: 2000
0:125
1 to 125: Specify the maximum number.
Other than above: 125
0:125
1 to 125: Specify the maximum number.
Other than above: 125
0:800
1 to 800: Specify the maximum number.
Other than above: 800
When Bit0 of GS570 is "1", the function code "0F" is not
used, and therefore the setting of GS575 will be disabled.
0:100
1 to 100: Specify the maximum number.
Other than above: 100
When Bit1 of GS570 is "1", the function code "10F" is not
used, and therefore the setting of GS576 will be disabled.
Set value
Set value