Trusted Platform Module; Installing The Trusted Platform Module - Dell PowerEdge C6320p Owner's Manual

Hide thumbs Also See for PowerEdge C6320p:
Table of Contents

Advertisement

3.
Take the sled out of the enclosure.
4.
Remove the system battery.
Steps
1.
Locate the battery socket. For more information, see the System board connectors section.
2.
Insert the battery into the socket and push down till it clicks in place.
Figure 72. Installing the system battery - clamp type holder
Next steps
1.
Install the sled into the enclosure.
2.
Follow the procedure listed in the After working inside your system section.
3.
While booting, press F2 to enter System Setup and ensure that the battery is operating properly.
4.
Enter the correct time and date in the System Setup Time and Date fields.
5.
Exit System Setup.

Trusted Platform Module

Trusted Platform Module (TPM) is a dedicated microprocessor designed to secure hardware by integrating cryptographic keys into
devices. A software can use a Trusted Platform Module to authenticate hardware devices. As each TPM chip has a unique and
secret RSA key burned in as it is produced, it can perform the platform authentication.
CAUTION: Do not attempt to remove the Trusted Platform Module (TPM) from the system board. After the TPM is
installed, it is cryptographically bound to that specific system board. Any attempt to remove an installed TPM breaks the
cryptographic binding, and it cannot be re-installed or installed on another system board.
NOTE: This is a Field Replaceable Unit (FRU). Removal and installation procedures must be performed only by Dell
certified service technicians.

Installing the Trusted Platform Module

Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and
simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support
team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety
instructions that are shipped with your product.
NOTE: There is a TPM slot on the system board of each sled.
1.
Follow the safety guidelines listed in the Safety instructions section.
2.
Follow the procedure listed in the Before working inside your system section.
3.
Remove the sled from the enclosure.
4.
If installed, remove the mezzanine card.
126

Advertisement

Table of Contents