Power And System Board Indicator Codes - Dell PowerEdge C6320p Owner's Manual

Hide thumbs Also See for PowerEdge C6320p:
Table of Contents

Advertisement

Convention
C
D
E

Power and system board indicator codes

The LEDs on the enclosure front panel and back panel display status codes during system startup and operation. For location of the
LEDs on the front panel, see the Front panel features and indicators section. For location of the LEDs on the back panel, see the
Back panel features and indicators section.
Table 8. Status indicator codes
Component
Power-on indicator (A bi-color
LED on power button)
22
Power Indicator Pattern
Flashes green and turns off
Flashing amber
Not lit
Indicator
Green
Solid
Amber
Off
Green
Off
Amber
Blinking
Green
Off
Description
NOTE: Mixing PSUs from previous
generations of Dell PowerEdge
servers will result in a PSU
mismatch condition or failure to
turn the system on.
When hot-adding a PSU, the PSU LED
flashes green five times at 4 Hz rate and
turns off. This indicates that there is a
PSU mismatch with respect to efficiency,
feature set, health status, and supported
voltage.
Indicates a problem with the PSU.
CAUTION: When correcting a PSU
mismatch, replace only the PSU
with the flashing indicator.
Swapping the other PSU to make a
matched pair can result in an error
condition and unexpected system
shutdown. To change from a High
Output configuration to a Low
Output configuration or vice versa,
you must turn off the system.
NOTE: AC PSUs support both 220
V and 110 V input voltages. When
two identical PSUs receive
different input voltages, they can
output different wattages, and
trigger a mismatch.
CAUTION: If two PSUs are used,
they must be of the same type and
have the same maximum output
power.
Power is not connected.
Condition
Power On (S0)
iDRAC critical condition event in Power Off mode (S4/S5)
iDRAC critical condition event in Power On mode (S0)