Configuration Procedure; Configuring The Software Exception Handling Method For Mpus; Rebooting A Card Or Switch - HP A7500 Series Configuration Manual

Hide thumbs Also See for A7500 Series:
Table of Contents

Advertisement

<System> system-view
[System] header shell AHave a nice day.
Please input banner content, and quit with the character 'A'.――System prompt
Please input the Password!A

Configuration procedure

Follow these steps to configure banners:
To do...
Enter system view
Configure the incoming banner
Configure the login banner
Configure the legal banner
Configure the shell banner
Configure the MOTD banner
Configuring the software exception handling
method for MPUs
The following are the software exception handling methods available for an MPU:
reboot—The MPU automatically reboots to recover from the error condition.
maintain—The MPU stays in the error condition so you can collect complete data, including error
messages, for diagnosis. In this approach, you must manually reboot the MPU.
In an IRF fabric, the software exception handling method applies to all member switches.
Follow these steps to configure the software exception handling method for MPUs:
To do...
Enter system view
Configure the exception handling
method for the MPUs
NOTE:
An LPU always reboots to recover from a software exception condition.

Rebooting a card or switch

You can reboot a card or switch in one of the following ways to recover from an error condition:
Reboot the card or switch immediately at the CLI.
At the CLI, schedule a reboot to occur at a specific time and date or after a delay.
Use the command...
system-view
header incoming text
header login text
header legal text
header shell text
header motd text
Use the command...
system-view
system-failure { maintain | reboot }
155
Remarks
Optional
Optional
Optional
Optional
Optional
Remarks
Optional
By default, an MPU reboots to
recover from a software exception
condition.