Restoring The Control System With The Start-Up Archive File - Siemens SINUMERIK 808D Commissioning Manual

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

7.2.3

Restoring the control system with the start-up archive file

You can, if necessary, restore the system of the prototype machine by uploading the start-up
archive file.
To upload the start-up archive, perform the following operations:
1. In the "SYSTEM" operating area, press the "Archv." softkey.
2. Select the option "Restore start-up archive":
Press the "OK" softkey:
3. Find the backed-up path and press the <INPUT> key to enter the directory. Select the
backed-up data archive and press the "OK" softkey:
4. Check the archive information and press the "OK" softkey to proceed if the selected data
archive is correct:
Commissioning Manual
Commissioning Manual, 01/2015, 6FC5397-4EP10-0BA0
Commissioning the prototype
7.2 Data backup
73