Creating A Start-Up Archive For The Prototype - Siemens SINUMERIK 808D Commissioning Manual

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

3. Press the <INPUT> key to enter selected directory and press the "OK" softkey to
proceed:
In the "Archive information" box that follows, you can enter the following information:
– Archive creator
– Archive version
– Comment
4. Press the "OK" softkey to create the data archive.
Note
Do not remove the USB stick during the data back-up.
7.2.2

Creating a start-up archive for the prototype

After commissioning the prototype, you must also create a start-up archive for the data
backup of the prototype itself.
The start-up archive file includes the following data:
● Machine and setting data
● Compensation data
● PLC data (for example, PLC program and PLC alarm texts)
● User cycles and part programs
● Tool and work offset data
● R variables
● HMI data (for example, OEM Online Help and OEM Manual)
You can also back up the start-up archive in two ways:
● Internal: on the CNC controller
● External: on an USB stick
Commissioning Manual
Commissioning Manual, 01/2015, 6FC5397-4EP10-0BA0
Commissioning the prototype
7.2 Data backup
71