Other Faults; Display Data List; A.6.2.4 Other Faults - Siemens SINUMERIK 808D Commissioning Manual

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Appendix
A.6 Diagnostics
A.6.2.4

Other faults

1. Motor speed incorrect
– Description: The actual motor position is always wrong, and the motor speed is not
– Cause: The pulse signal from the NC to drive is incorrect.
– Remedy: Check the pulse signal line connection
2. Brake not open
– Description: The brake is not open when the drive is in "S-Run" state.
– Cause: A short circuit has occurred in the brake cable.
– Remedy: Check brake cable connection
A.6.2.5

Display data list

Data No.
Name
D10
Torque setpoint
1)
D11
Actual value of the torque
1)
D12
Actual value of the phase cur-
1)
rent
D20
Motor speed setpoint
D21
Actual motor speed
D30
Position revolution setpoint
D31
Position angle setpoint
D32
Actual position revolutions
D33
Actual position angle
D34
Position deviation angle
D50
Digital input signal
1)
D51
Digital output signal
1)
D80
Firmware version
1)
D81
Power Board rated current
D82
Parameter version number
1)
The data type of D10, D11, D12, D80, D82 is in all decimal format. The display value for D50 and D51 respectively
1)
varies as the case requires.
104
right, either.
Data format
Decimal
(See table below)
Integer
Bit (See table below)
(See table below)
Integer
(See table below)
Unit
Nm
Nm
A
RPM
RPM
Motor revolutions
Increments (10000/r)
Motor revolutions
Increments (10000/r)
Increments (10000/r)
Bits in hex
Bits in hex
Commissioning Manual, 01/2015, 6FC5397-4EP10-0BA0
Data group
Current
Speed
Position
I/O
HW, FW
Commissioning Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents