Mounting
2.2 Mounting the drive
Figure 2-5
Mounting method
With 4xM5 preassembled screws, the drive can be mounted vertically onto the inner panel of
the cabinet. The maximum screw torque must be 2.0 Nm.
Minimum mounting clearance
To ensure adequate cooling, as a minimum, maintain the specified clearance between
drives, one drive and another device/inner panel of the cabinet.
Figure 2-6
Using the cable clamps supplied
If the CE marking requirements for cables are mandatory, the line supply cable and the
power cable used must all be shielded cables. In this case, you can use the cable clamps as
a ground connection between the cable shield and a common ground point.
Clamps can also be helpful in better fixing cables (the unshielded power cable and the line
supply cable) in place.
16
10 A version (in mm)
Drive mounting clearance (in mm)
Commissioning Manual, 01/2015, 6FC5397-4EP10-0BA0