Commissioning the prototype

7.1

Commissioning the controller

7.1.1

Entering machine data

Note
Make sure that the current access level is "Manufacturer".
The most important machine data of the individual subareas are listed here to assist you.
You can find a detailed description of the machine data and interface signals in the
Parameter Manual
Entering the machine data (MD)
Use the relevant softkeys to select the following machine data areas and to change the
machine data if necessary:
● Basic list ("SYSTEM" operating areas -> "Mach. data" -> "Basic list")
– Basic machine data
● Expert list ("SYSTEM" operating areas -> "Mach. data" -> "Expert list")
– General machine data
– Axis machine data
– Channel machine data
– Display machine data
Activating conditions
The control system has defined four activating conditions. Each machine has a
corresponding activating condition:
● PO: Power On (activate by powering on)
● RE: Reset (activate by pressing the "RESET" key)
● CF: Config (activate by pressing the "Activate" vertical softkey)
● IM: Immediate (activated immediately after your change)
Note
The activating condition for a machine data is shown at the end of the data line in the
parameter lists. For information about basic machine data, refer to the section "Basic
machine data (Page 93)"; for information about all the machine data, refer to the
SINUMERIK 808D Parameter Manual