Appendix
E
Updating Firmware on 1600T Cameras
Use DHCP: 0 - 1
Save parameters to flash? [y/n] - y
Saving boot parameters to flash......done.
Network Name — This is limited to 19 characters. Any input string longer
•
than 19 characters is truncated automatically to the first 19 characters. The
string is erased by entering the '.' (period) character.
Static IP, Subnet Mask, Gateway — These must contain an address in
•
valid IP format. If you enter an invalid address, you are prompted to re-enter
the value until a valid address is entered or the Enter key is pressed
(effectively skipping the update for this field).
•
DHCP — The value for DHCP value is either a 0 (zero) or 1 (one).
MAC Address — You cannot change the MAC Address, since this is set in
•
the factory.
Reset User Account
Each Visionscape
combination where the password is encrypted using the unit's MAC address. The
Reset User Account utility allows you to reset the User/Password combination to
the default values of:
User: hawkeye
Password: vision
Resetting the account is password protected with the string vision.
>> 2
Enter password to reset User Account to defaults: ******
Exit to Application
The Exit to Application selection exits the Main Menu and switches execution to
the beginning of application code stored in Non-Volatile memory. If there is no
valid application program in Non-Volatile memory, the Main Menu is
re-displayed.
E-8
®
Smart Camera HE1600T is protected by a User/Password
Visionscape® Smart Camera HE1600T Guide
Rev. 1H, Mar 2009
Need help?
Do you have a question about the Visionscape HE1600T and is the answer not in the manual?
Questions and answers