H1: Multi-Function Digital Inputs

No.
(Addr.
Name
Hex)
Multi-Function Digital Input
H1-03
Terminal S3 Function
(400)
Selection
Term S3 Func Sel
Multi-Function Digital Input
H1-04
Terminal S4 Function
(401)
Selection
Term S4 Func Sel
Multi-Function Digital Input
H1-05
Terminal S5 Function
(402)
Selection
Term S5 Func Sel
Multi-Function Digital Input
H1-06
Terminal S6 Function
(403)
Selection
Term S6 Func Sel
Multi-Function Digital Input
H1-07
Terminal S7 Function
(404)
Selection
Term S7 Func Sel
H1-oo
Function
Setting
Multi-Step Speed Reference 1
3
Multi-Step Ref 1
Multi-Step Speed Reference 2
4
Multi-Step Ref 2
Jog reference selection
6
Jog Freq Ref
Analog terminal input selection
C
Term AI Enable
<1>
Not Used (Through Mode)
F
Up command
10
Up Command 1
Down command
11
Down Command 1
Reverse Jog
<2>
13
Reverse Jog
14
Fault Reset
PI disable
19
PI Disable
External fault
NO/Always Det
24
Coast to Stop
Motor pre-heat 1
60
Motor Preheat 1
<1> Available in bypass controller software versions VST800298 and later.
<2> Available in bypass controller software versions VST800297 and earlier.
YASKAWA ELECTRIC SIEP YAIZ1B 01E YASKAWA AC Drive – Z1000 Bypass Technical Manual
Description
Assigns a function to the multi-function digital inputs through Z2-oo = 3.
Refer to
Table B.3
for descriptions of setting values.
Note:
Set unused terminals to F.
Assigns a function to the multi-function digital inputs through Z2-oo = 4.
Refer to
Table B.3
for descriptions of setting values.
Note:
Set unused terminals to F.
Assigns a function to the multi-function digital inputs through Z2-oo = 5.
Refer to
Table B.3
for descriptions of setting values.
Note:
Set unused terminals to F.
Assigns a function to the multi-function digital inputs through Z2-oo = 6.
Refer to
Table B.3
for descriptions of setting values.
Note:
Set unused terminals to F.
Assigns a function to the multi-function digital inputs through Z2-oo = 7.
Refer to
Table B.3
for descriptions of setting values.
Note:
Set unused terminals to F.
Table B.3 H1 Multi-Function Digital Input Selections
When input terminals are set to Multi-Step Speed References 1 through 3, switching
combinations of those terminals will create a multi-step speed sequence using the frequency
references set in d1-01 through d1-08.
When input terminals are set to Multi-Step Speed References 1 through 3, switching
combinations of those terminals will create a multi-step speed sequence using the frequency
references set in d1-01 through d1-08.
Closed: Jog frequency reference (d1-17) selected. Jog has priority over all other reference
sources.
Open: Function assigned by H3-14 is disabled.
Closed: Function assigned by H3-14 is enabled.
Allows serial communications to control the output.
The drive accelerates when the Up command terminal closes, and decelerates when the Down
command closes. When both terminals are closed or both are open, the drive holds the
frequency reference. The Up and Down commands must always be used in conjunction with
one another.
The drive accelerates when the Up command terminal closes, and decelerates when the Down
command closes. When both terminals are closed or both are open, the drive holds the
frequency reference. The Up and Down commands must always be used in conjunction with
one another.
Closed: Runs reverse at the Jog frequency d1-17
Closed: Resets faults if the cause is cleared and the Run command is removed.
Open: PI control enabled
Closed: PI control disabled
Normally Open, Always Detected, Coast to Stop
Closed: Triggers Motor pre-heat 1
B.8 H Parameters: Multi-Function Terminals
Description
Values
Page
Default: 24
Min.: 3
151
Max.: 60
Default: 14
Min.: 3
151
Max.: 60
Default: 3
Min.: 3
151
Max.: 60
Default: 4
Min.: 3
151
Max.: 60
Default: 6
Min.: 3
151
Max.: 60
Page
151
151
151
151
151
151
151
152
153
153
153
153